Scribner  |  SKU: 857

857 Redox Flow Cell Test System

€0,00


Delivery and Shipping to EU

We will add in the quotation, the shipping, insurance, customs clearance costs.

857 Redox Flow Cell Test System

Scribner

The 857 is an Integrated Turn-Key Test System for Redox Flow Cell Research & Development. It boasts a 20 A current range as well as a multi-range potentiostat for high accuracy. Included with the system is the powerful, user friendly FlowCell software for system operation & experimentation.

  • 0.07 A, .07 A, 7 A, 20 A current range
  • High-current, multi-range potentiostat operates in current- or voltage-controlled operation
  • ± 5 V operation for non-aqueous electrolytes
  • Charge / discharge cycling & performance characterization
  • Four reservoir sizes- 100 mL, 250 mL, 500 mL, and 1 L
  • Whole and half-cell voltage, EIS and HFR measurement
  • Impedance Analyzer for EIS and HFR measurements during charge, discharge and at OCV
  • High-impedance V-sense inputs for whole and half-cell measurements including EIS & HFR
  • State-of-charge (SOC) voltage inputs for DC SOC measurement when used with SOC cell
  • All non-metallic electrolyte handling system: pumps, electrolyte reservoirs, drain and purge valves
  • Cell and electrolyte temperature control up to 50 oC
  • Peristaltic pumps with variable flow control including forward and reverse
  • Electrolyte shielding with inert gas purge blanket
  • Electrolyte reservoir stirring

 

Specification: Details
Potentiostat:
Current Ranges: 20 A, 7 A, 700 mA, 70 mA full scale (FS)
Current Resolution: 1.4 mA (20 A FS) to 4.88 µA (70 mA FS)
Current Accuracy: ± 1% of full scale current of selected range
Voltage Measurement and Data Acquisition:
Set and Read Voltage vs. WE: ± 5.000 V
Cell Voltage Sense Leads: Differential with driven shields
Voltage Measurement Resolution: 152 µV
Sense Lead Input Resistance: 1 GΩ
Data Acquisition Rate: 10 points/second
Impedance Analyzer:
Internal Impedance Analyzer Type: Single sine, one generator and two gain/phase measurement channels
Internal Analyzer Frequency Range: 1 mHz to 10 kHz
Electrolyte Fluid Handling System: Computer-controlled peristaltic pumps (2); <1 to 1,000 mL/min
All non-metallic flow path and reservoirs
Independent drain & purge valves for positive & negative electrolytes
Nitrogen purge and blanket; Electrolyte level monitoring
Temperature Controllers:
Three: Cell, anode electrolyte, cathode electrolyte
Set & Report Accuracy: ±0.25% of span, ±1 least significant digit
Sensor Type: Thermocouple, Type T
Environment:
Operating Temperature: 5 to 35 °C
Power Source: 110-120 V, 50-60 Hz, 10 A (Export model 220-240 V, 50-60 Hz, 5 A)
Size and Weight: Electronic Control Unit: 48 W x 13 H x 53 D cm3 (19 x 5.25 x 21 in3); 9 kg (20 lb)
Fluid Control Unit: 50 W x 65 H x 65 D cm3 (20 x 25 x 25 in3); 16 kg (35 lb)
Safety Features: Automatic shutdown on under- and over-voltage or current, over-temperature, or communications failure
Emergency stop switch for manual operator shutdown
*Specifications for 25o C ambient temperature unless otherwise noted.
SIGRACELL® is a registered trademark of SGL Carbon SE