BaSyTec XCTS Mk II
Couldn't load pickup availability
Delivery and Shipping to EU
Delivery and Shipping to EU
We will add in the quotation, the shipping, insurance, customs clearance costs.
BaSyTec XCTS Mk II
BaSyTec
The second generation BaSyTec XCTS Mk II Battery Test system is the replacement of our successful XCTS with 25A or 50A channels. It is made for test and formation of single cell batteries up to 6V and 800A.
The new XCTS has more power and much better precision than before.
Of course also the XCTS MK II is controlled by our powerful and comfortable BaSyTest Battery Test Software.
Advantages:
• 40A, 60A or 80A output
• Parallel operation for up to 800A
• High precision
• Gold plated connectors
• Small size (19“ form factor)
• High energy density
• Up to 3 automatically dynamically switching current ranges for up to 1mA precision
• Energy recovery, optional to the grid for high energy efficiency
• Powerful and comfortable BaSyTest software
Technical data
40A | 60A | 80A | |
Max. current/chan. | 40A | 60A | 80A |
Max. Power/chan. | 200W | 300W | 400W |
Parallel operation | Yes, 80A | Optional, 600A | Optional, 800A |
Range switching | Automatic and dynamic | Automatic and dynamic | Automatic and dynamic |
Chans/Unit | 8 or 20 | 5, 10 or 12 | 4 or 10 |
Voltage range | 0-6V | 0-6V | 0-6V |
Min. disch. volt | 1V | 1V | 1V |
Resolution | 0.1mV / 1mA | 0.1mV / 0.05mA | 0.1mV / 1mA |
Accuracy | 1mV, 10mA +0.1% up to 20A | 1mV, 1mA +0.1% up to 1.5A, 10mA +0.1% up to 20A, 30mA +0.1% up to 60A | 1mV, 10mA +0.1% up to 20A, 20mA +0.1% up to 40A, 40mA +0.1% up to 80A |
Measurement | Voltage (4W), current, temperature | Voltage (4W), current, temperature | Voltage (4W), current, temperature |
Temp. input type | NTC 5k (precision +/-2K) Epcos B57861S0502 or GE TK95 | NTC 5k (precision +/-2K) Epcos B57861S0502 or GE TK95 | NTC 5k (precision +/-2K) Epcos B57861S0502 or GE TK95 |
Time res./rise time | 1µs / 1ms | 1µs / 1ms | 1µs / 1ms |
Sampling rate | Peak 0.5ms, Min. 10ms but not more than 1kHz continually per system | Peak 0.5ms, Min. 10ms but not more than 1kHz continually per system | Peak 0.5ms, Min. 10ms but not more than 1kHz continually per system |
Current/voltage ripple | < 0.01%FS / < 0.5mV | < 0.01%FS / < 0.5mV | < 0.01%FS / < 0.5mV |
Control mode | Current, voltage, power, resistance and combinations | Current, voltage, power, resistance and combinations | Current, voltage, power, resistance and combinations |
Energy recovery | Yes, between the channels | Yes, between the channels | Yes, between the channels |
Recovery to the grid | Optional, total efficiency up to 70% (charge) / 60% (discharge) | Optional, total efficiency up to 70% (charge) / 60% (discharge) | Optional, total efficiency up to 70% (charge) / 60% (discharge) |
Software | BaSyTest | BaSyTest | BaSyTest |
Interface | Ethernet | Ethernet | Ethernet |
Connector | D-SUB 7W2 | D-SUB 9W4 | D-SUB 9W4 |
Noise | 70 - 85dB(A) (without recovery to the grid) | 60 - 83dB(A) (with recovery to the grid) | 60 - 83dB(A) (with recovery to the grid) |
Size/weight/Supply (No recovery to the grid) | 450mm310 (180)mm500mm, 40kg (25kg), 400VAC / 50Hz / 3 phases+N (230VAC / 16A) | 450mm310 (180)mm500mm, 40kg (25kg), 400VAC / 50Hz / 3 phases+N (230VAC / 16A) | 450mm310 (180)mm500mm, 40kg (25kg), 400VAC / 50Hz / 3 phases+N (230VAC / 16A) |
Size/weight/Supply (Recovery to the grid) | 450310620mm, 70kg, 400VAC / 50Hz / 3 phases+N | 450310620mm, 70kg, 400VAC / 50Hz / 3 phases+N | 450310620mm, 70kg, 400VAC / 50Hz / 3 phases+N |