Replacement Trace Oxygen Sensor - EQ-W1000-Sensor-LD

€0,00

Sensor Type

Delivery and Shipping to EU

We will add in the quotation, the shipping, insurance, customs clearance costs.

Replacement Trace Oxygen Sensor - EQ-W1000-Sensor-LD

MTI

Replacement sensor for EQ-W1000-LD Trace Oxygen Analyzer.
Warning Sensor should only be used with flowing inert gas. Never use it under vacuum conditions, otherwise, damage to the sensor could occur.
 
Please Note, the sensor is nonrefundable.

SPECIFICATIONS

Replaces the sensor in EQ-W1000-LD:


(Analyzer & Sensor Housing NOT included)
Available in two versions: Glove Box and Furnace, please select from the Product Options above. 
  • Micro fuel cell technology
  • Accuracy:                                        +/- 1% Full-Scale Range
  • Repeatability:                                  +/- 0.5% Full Scale
  • Temperature Coefficient:                 2.54%/ ºC
  • Operating Temperature:                  0 to 50 ºC
  • Storage Temperature:                     0 to 45 ºC
  • Recommended Gas Flow:              0.5 - 2 SCFH (Standard Cubic Feet per Hour) Furnace Sensor
  •                                                         0.5 - 5 SCFH Glovebox Sensor
  • Humidity:                                         0 - 100% Relative; Non-Condensing
  • Longevity:                                         17 - 25 Months
Sensor Types
Glove Box Sensor
Provides the best response when used in enclosed environments where battery R&D is conducted; measures trace oxygen levels in purge gases (e.g. N2 and Argon).
                       (Image for reference only, Glove Box system is NOT included)
Furnace Sensor
Designed for CVD applications when acid and aggressive gases (e.g. CO2, HCI, HCN, and etc.) will be present.
                         (Image for reference only, Furnace system is NOT included)
Weight 1 lb
Notes & Warnings
  • The analyzer is designed for measuring trace oxygen in the presence of gas flow; it may not measure reliably when gas is static.
  • NEVER use the oxygen sensor under vacuum conditions. The vacuum will cause irreversible damage to the sensor.
  • ONLY USE the furnace oxygen sensor with CVD furnace systems to prevent contamination and damage to the sensor.
    • To prevent sensor damage, please use quick ON/OFF valves to isolate the sensor from open-air and maintain it with an inert gas at all times. Click the picture below to learn more about this setup:
                     
  • Due to the variations in electronics and sensor technology, minor deviations in O2 reading performance may be experienced when using O2 analyzers or sensors from a different brand, technology, and etc.
  • The oxygen sensor is consumable and not covered by warranty, damage caused by misuse is also excluded from coverage.